Features
● Input power: 2W , 5W , 10W
● Available in step adjusting
● Wide frequency range: DC ~ 6GHz
● Low VSWR, Low ion loss
● Sealed structure moisture-proof & damp-proof, can be work outdoors in harsh condition
● Easy to operate, adjustment results visually readable
● Step series has locking devices within each attenuation, shockproof capability
● Can reach over 5000 times adjustment
● Easy to adjust,widely used in production line,or to be installed in the system & device for signal control
|
|
|
|
Model Description
|
VAX
|
**
|
**
|
*
|
**
|
|
|
Freq.Range
|
Attenuatin Range
|
Step Value
|
Power
|
|
|
Freq.Range:06 represents DC to 6GHz
|
Attenuation Range:10 represents 0~10dB.
|
Step Value : 01 represents step value 1dB.
|
Power:“2”represents2W,“5”represents5W,“10”represents10W.
|
|
|
e.g. : VAX06100110
|
|
|
|
SMA Type Series
Step Type Spec.
|
|
● Freq.Range: DC to 6GHz ● Attenuatin Range: 0-1(dB) or 0-10(dB) or 0-90(dB) ● Power: 2W , 5W ,10W
●Impedance: 50Ω ● Operating temperature: -40℃ ~ +85℃
|
|
Model
|
Attenuation Range
(dB)
|
Power
(W)
|
Step Value
(dB)
|
Attenuation Accuracy
(dB)
|
VSWR:1 (Max.)
|
|
outside view
|
DC ~ 6GHz
|
DC ~ 6GHz
|
VAX0601P1 NEW
|
0 ~ 1
|
5 or 10
|
0.1
|
±0.5
|
1.5
|
50
|
|
VAX061001 NEW
|
0 ~ 10
|
5 or 10
|
1
|
±0.5
|
1.5
|
50
|
|
0 ~ 90
|
5 or 10
|
10
|
±0.7
|
1.5
|
50
|
|
|
SMA Type Series
Step Type Spec.
|
|
● Freq.Range: DC to 6GHz ● Attenuatin Range: 0-11(dB) or 0-70(dB) or 0-90(dB) ● Power: 2W , 5W ,10W
● Impedance: 50Ω ●Operating temperature: -40℃ ~ +85℃
|
|
Model
|
Attenuation Range
(dB)
|
Power
(W)
|
Step Value
(dB)
|
Attenuation Accuracy
(dB)
|
VSWR:1 (Max.)
|
|
outside view
|
DC ~ 6GHz
|
DC ~ 6GHz
|
VAX0611P1 NEW
|
0 ~ 11
|
5 or 10
|
0.1
|
±0.5
|
1.30
|
50
|
|
|
0 ~ 70
|
5 or 10
|
1
|
±0.5
|
1.30
|
50
|
|
0 ~ 90
|
5 or 10
|
1
|
±0.7
|
1.30
|
50
|
|
|
SMA Type Series
Step Type Spec.
|
|
● Freq.Range: DC to 6GHz ● Attenuatin Range: 0-11(dB) or 0-70(dB) or 0-90(dB) ● Power: 2W , 5W ,10W
● Impedance: 50Ω ● Operating temperature: -40℃ ~ +85℃
|
|
Model
|
Attenuation Range
(dB)
|
Power
(W)
|
Step Value
(dB)
|
Attenuation Accuracy
(dB)
|
VSWR:1(Max.)
|
|
outside view
|
DC ~ 6GHz
|
DC ~ 6GHz
|
VAB061101 NEW
|
0 ~ 11
|
5 or 10
|
1
|
±0.5
|
1.30
|
50
|
|
|
0 ~ 70
|
5 or 10
|
1
|
±0.5
|
1.30
|
50
|
|
0 ~ 90
|
5 or 10
|
1
|
±0.7
|
1.30
|
50
|
|
|
|
Return to Switch/Rotary Variable Attenuator
|
|
|
|
|